Publication

Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs

Schuller, A. A. & Holst, D., Nov-1996, In : Journal of Clinical Periodontology. 23, 11, p. 977-81 5 p.

Research output: Contribution to journalArticleAcademicpeer-review

APA

Schuller, A. A., & Holst, D. (1996). Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs. Journal of Clinical Periodontology, 23(11), 977-81. https://doi.org/10.1111/j.1600-051X.1996.tb00523.x

Author

Schuller, A A ; Holst, D. / Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs. In: Journal of Clinical Periodontology. 1996 ; Vol. 23, No. 11. pp. 977-81.

Harvard

Schuller, AA & Holst, D 1996, 'Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs', Journal of Clinical Periodontology, vol. 23, no. 11, pp. 977-81. https://doi.org/10.1111/j.1600-051X.1996.tb00523.x

Standard

Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs. / Schuller, A A; Holst, D.

In: Journal of Clinical Periodontology, Vol. 23, No. 11, 11.1996, p. 977-81.

Research output: Contribution to journalArticleAcademicpeer-review

Vancouver

Schuller AA, Holst D. Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs. Journal of Clinical Periodontology. 1996 Nov;23(11):977-81. https://doi.org/10.1111/j.1600-051X.1996.tb00523.x


BibTeX

@article{e8b040fabe0f4407ab78c58a70b556e5,
title = "Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs",
abstract = "UNLABELLED: The purpose of the research described in this paper is to test the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest (CJ-AC) on bitewing radiographs. The present paper shows how the consistency tests were organized and which statistical analyses were used. Since the actual characteristic (CJ-AC) could not alter, the variations of the results had to be due to one more of the 5 m-factors (man, material, machine, method and manipulation). To test the consistency of the measurements of CJ-AC, a pretest and an en route test were performed. Both the bitewing radiographs for the pretest and the en route test were sampled at random from the principal material. The principal material consisted of 856 sets of bitewing radiographs from persons born 1930-1949. The pretest of 40 sets of bitewing radiographs were read twice by 2 independent readers. The en route test consisted of 85 sets of bitewing radiographs which were read twice by 1 reader. Neither the results of the pretest nor the results of the en route test showed statistical or clinical differences of significance.IN CONCLUSION: the consistency of this method of measuring is satisfactory for the 2 readers.",
keywords = "Aged, Alveolar Bone Loss, Analysis of Variance, Humans, Middle Aged, Observer Variation, Radiography, Bitewing, Regression Analysis, Reproducibility of Results, Statistics, Nonparametric",
author = "Schuller, {A A} and D Holst",
year = "1996",
month = nov,
doi = "10.1111/j.1600-051X.1996.tb00523.x",
language = "English",
volume = "23",
pages = "977--81",
journal = "Journal of Clinical Periodontology",
issn = "0303-6979",
publisher = "Wiley",
number = "11",

}

RIS

TY - JOUR

T1 - Testing the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest on bitewing radiographs

AU - Schuller, A A

AU - Holst, D

PY - 1996/11

Y1 - 1996/11

N2 - UNLABELLED: The purpose of the research described in this paper is to test the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest (CJ-AC) on bitewing radiographs. The present paper shows how the consistency tests were organized and which statistical analyses were used. Since the actual characteristic (CJ-AC) could not alter, the variations of the results had to be due to one more of the 5 m-factors (man, material, machine, method and manipulation). To test the consistency of the measurements of CJ-AC, a pretest and an en route test were performed. Both the bitewing radiographs for the pretest and the en route test were sampled at random from the principal material. The principal material consisted of 856 sets of bitewing radiographs from persons born 1930-1949. The pretest of 40 sets of bitewing radiographs were read twice by 2 independent readers. The en route test consisted of 85 sets of bitewing radiographs which were read twice by 1 reader. Neither the results of the pretest nor the results of the en route test showed statistical or clinical differences of significance.IN CONCLUSION: the consistency of this method of measuring is satisfactory for the 2 readers.

AB - UNLABELLED: The purpose of the research described in this paper is to test the consistency of measurements of the distance between the cemento-enamel junction and the alveolar bone crest (CJ-AC) on bitewing radiographs. The present paper shows how the consistency tests were organized and which statistical analyses were used. Since the actual characteristic (CJ-AC) could not alter, the variations of the results had to be due to one more of the 5 m-factors (man, material, machine, method and manipulation). To test the consistency of the measurements of CJ-AC, a pretest and an en route test were performed. Both the bitewing radiographs for the pretest and the en route test were sampled at random from the principal material. The principal material consisted of 856 sets of bitewing radiographs from persons born 1930-1949. The pretest of 40 sets of bitewing radiographs were read twice by 2 independent readers. The en route test consisted of 85 sets of bitewing radiographs which were read twice by 1 reader. Neither the results of the pretest nor the results of the en route test showed statistical or clinical differences of significance.IN CONCLUSION: the consistency of this method of measuring is satisfactory for the 2 readers.

KW - Aged

KW - Alveolar Bone Loss

KW - Analysis of Variance

KW - Humans

KW - Middle Aged

KW - Observer Variation

KW - Radiography, Bitewing

KW - Regression Analysis

KW - Reproducibility of Results

KW - Statistics, Nonparametric

U2 - 10.1111/j.1600-051X.1996.tb00523.x

DO - 10.1111/j.1600-051X.1996.tb00523.x

M3 - Article

C2 - 8951623

VL - 23

SP - 977

EP - 981

JO - Journal of Clinical Periodontology

JF - Journal of Clinical Periodontology

SN - 0303-6979

IS - 11

ER -

ID: 24006865