Publication

Influence of Cervical Crown Contour on Marginal Bone Loss Around Platform-Switched Bone-Level Implants: A 5-Year Cross-Sectional Study

Hentenaar, D. F., De Waal, Y. C., Van Winkelhoff, A. J., Raghoebar, G. M. & Meijer, H. J., 9-Jul-2020, In : International Journal of Prosthodontics. 33, 4, p. 373-379 7 p.

Research output: Contribution to journalArticleAcademicpeer-review

Copy link to clipboard

Documents

  • Aortic involvement in giant cell arteritis

    Final publisher's version, 2.95 MB, PDF document

    Request copy

DOI

PURPOSE: To evaluate the influence of the cervical crown contour on marginal bone loss and soft tissue health around platform-switched, posteriorly placed, two-piece implants.

MATERIALS AND METHODS: A dataset from two previously conducted studies was used. Patients with single two-piece, platform-switched implants in between two natural teeth or adjacent to one natural tooth were included. Clinical parameters and standardized periapical radiographs from 1 month and 5 years after final crown placement were assessed. A new measurement method was developed to analyze geometric values of the cervical crown contour. Inter- and intraexaminer reliability were assessed. Emergence angles were measured at 1, 2, and 3 mm above the implant shoulder. Linear correlations between variables were determined by calculating Pearson correlation coefficients.

RESULTS: A total of 64 patients with 67 posterior implants met the inclusion criteria. At 1, 2, and 3 mm above the implant shoulder, mean emergence angles at the mesial implant sites were 0.5 ± 2.8, 12.8 ± 12.8, and 18.0 ± 11.3 degrees, respectively. At the distal sites, the corresponding values were 2.8 ± 8.3, 16.2 ±16.6, and 18.7 ± 13.8 degrees, respectively. Mean marginal bone loss between 1 month and the 5-year evaluations was 0.14 ± 0.34 mm at the mesial aspect and 0.26 ± 0.47 at the distal aspect of implants. No correlation with peri-implant bone loss or soft tissue health could be found. No implants showed signs of peri-implantitis.

CONCLUSION: The cervical crown contour at platform-switched, posteriorly placed, two-piece implants showed no correlation with peri-implant marginal bone loss or soft tissue health up to 5 years after implant placement.

Original languageEnglish
Pages (from-to)373-379
Number of pages7
JournalInternational Journal of Prosthodontics
Volume33
Issue number4
Publication statusPublished - 9-Jul-2020

    Keywords

  • PERI-IMPLANTITIS, SOFT, RESTORATIONS, AGREEMENT, ACCURACY, AMALGAM, TISSUES, IMPACT

ID: 129136898