Analysis of new diagnostics and technologies in endovascular aortic aneurysm repair

van Noort, K., 2019, [Groningen]: University of Groningen. 222 p.

Research output: ThesisThesis fully internal (DIV)Academic

Copy link to clipboard

Documents

  • Title and contents

    Final publisher's version, 163 KB, PDF document

  • Chapter 1

    Final publisher's version, 626 KB, PDF document

  • Chapter 2

    Final publisher's version, 1 MB, PDF document

  • Chapter 3

    Final publisher's version, 1016 KB, PDF document

  • Chapter 4

    Final publisher's version, 1 MB, PDF document

  • Chapter 5

    Final publisher's version, 1 MB, PDF document

  • Chapter 6

    Final publisher's version, 1 MB, PDF document

  • Chapter 7

    Final publisher's version, 745 KB, PDF document

  • Chapter 8

    Final publisher's version, 1 MB, PDF document

  • Chapter 9

    Final publisher's version, 633 KB, PDF document

  • Chapter 10

    Final publisher's version, 528 KB, PDF document

  • Chapter 11

    Final publisher's version, 464 KB, PDF document

  • Chapter 12

    Final publisher's version, 392 KB, PDF document

  • Chapter 13

    Final publisher's version, 993 KB, PDF document

  • Chapter 14

    Final publisher's version, 466 KB, PDF document

  • Complete thesis

    Final publisher's version, 8 MB, PDF document

  • Propositions

    Final publisher's version, 501 KB, PDF document

The studies in this dissertation investigate new diagnostic and technologies in endovascular aneurysm repair (EVAR). In part I dedicated CT- analyses software is investigated that can detect subtle changes in endograft position and apposition. The early detection of endograft changes may lead to less invasive and expensive reinterventions before severe complications occur. Moreover, it may add to a more patient-specific follow-up scheme.

In part Ib the use of EndoAnchors are analysed. Almost 30% of the EndoAnchor implants for treatment of acute or late endoleaks are maldeployed. In the majority of these cases this is due to the use of EndoAnchors beyond the recommended use. For that reason careful preoperative planning and optimization of the intra-operative deployment technique need to be performed. If however, the EndoAnchors are positioned correctly durability is good.

In part II a new stenting method is analysed. Endovascular aneurysm sealing (EVAS) uses polymer filled endobags to fill the aneurysm sac, to provide total sealing and stability of the endograft in the aorta. The studies in this part of the dissertation investigate different directions of migration, accuracy of deployment and preoperative anatomical characteristics that may predict complications. These studies show that in 30% of the patients treated with EVAS complication occur at mid-term follow-up. These complication may be a result of unstable configuration of the EVAS device.
Original languageEnglish
QualificationDoctor of Philosophy
Awarding Institution
Supervisors/Advisors
Award date8-Jul-2019
Place of Publication[Groningen]
Publisher
Print ISBNs978-94-034-1756-1
Electronic ISBNs978-94-034-1755-4
Publication statusPublished - 2019

View graph of relations

Download statistics

No data available

ID: 84971014