A prospective multicenter clinical feasibility study of a new automatic speaking valve for postlaryngectomy voice rehabilitation

Lansaat, L., de Kleijn, B. J., Hilgers, F. J. M., van der Laan, B. F. A. M. & van den Brekel, M. W. M., Feb-2017, In : European Archives of Oto-Rhino-Laryngology. 274, 2, p. 1005-1013 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

Evaluation of short- and long-term clinical feasibility and exploration of limitations and advantages of a new automatic speaking valve (ASV) for laryngectomized patients with integrated HME, the Provox FreeHands FlexiVoice (FlexiVoice). This ASV not only enables automatic, but also manual closure of the valve. A multicenter, prospective clinical study in 40 laryngectomized patients was conducted. Participants were asked to use the FlexiVoice for 26 weeks. The primary outcome measure was long-term compliance. Secondary outcome measures were: patient preference, hours of FlexiVoice use, device life of adhesive, voice and speech quality, and quality of life. After 26 weeks, 15 patients (37.5 %) were using the FlexiVoice on a daily basis, for a mean of 12.64 h/day (SD +/- 5.03). Ten patients (25 %) were using the device on a non-daily basis, for a mean of 3.76 h/day (SD +/- 2.07). The remaining 15 patients (37.5 %) discontinued using the FlexiVoice. Sixty percent of the 25 long-term users applied both automatic and manual closure of the valve. Unpredictable fixation of the adhesive was the main reason for discontinuing or not using the FlexiVoice on a daily basis. Overall, 18 patients (45 %) preferred the FlexiVoice, 16 patients (40 %) their usual HME, 3 patients (7.5 %) their usual ASV, 1 patient (2.5 %) preferred no device at all, and in 2 patients preference was not recorded. The minor technical issues identified could be corrected. The Provox FreeHands FlexiVoice appears to be a useful ASV, which allows for hands-free speech in a larger proportion of laryngectomized patients in the present cohort. The additional manual closure option of the device is beneficial for maintaining the adhesive seal longer.

Original languageEnglish
Pages (from-to)1005-1013
Number of pages9
JournalEuropean Archives of Oto-Rhino-Laryngology
Volume274
Issue number2
Publication statusPublished - Feb-2017

    Keywords

  • Total laryngectomy, Automatic speaking valve, Heat and moisture exchanger, Compliance, Voice, HANDS-FREE SPEECH, TRACHEOSTOMA VALVE, TOTAL LARYNGECTOMY, PULMONARY REHABILITATION, MOISTURE EXCHANGER, PATIENT, HEAT, RESTORATION, IMPROVEMENT, RETAINER

Download statistics

No data available

ID: 40983209