Dataset

Data: Coronary calcium scoring with partial volume correction in anthropomorphic thorax phantom and screening chest CT images

Sprem, J. (Creator), de Vos, B. D. (Creator), Lessmann, N. (Creator), van Hamersvelt, R. W. (Creator), Greuter, M. (Creator), de Jong, P. A. (Creator), Leiner, T. (Creator), Viergever, M. A. (Creator), Isgum, I. (Creator), Utrecht University, 10-Dec-2018

Dataset

  • Jurica Sprem (Creator)
  • Bob D. de Vos (Creator)
  • Nikolas Lessmann (Creator)
  • Robbert W van Hamersvelt (Creator)
  • Marcel Greuter (Creator)
  • Pim A de Jong (Creator)
  • Tim Leiner (Creator)
  • Max A. Viergever (Creator)
  • Ivana Isgum (Creator)
  • Univ Med Ctr Utrecht, University of Utrecht, Image Sci Inst

Description

Phantom DICOMs
DICOM images of CEORA and SATI phantom for calcium volume scores acquired using clinical calcium score and partial volume corrected scores.
Gathered results for calcium volume scores on two phantoms and clinical subjects acquired using clinical calcium score and partial volume corrected scores.

Two phantoms containing artificial coronary artery calcifications and 293 subject chest CT
scans were used. The first and second phantom contained nine calcifications and the second phantom contained three artificial arteries with three calcifications of different volumes,
shapes and densities. The first phantom was scanned five times with and without extension
rings. The second phantom was scanned three times without and with simulated cardiac
motion (10 and 30 mm/s). Chest CT scans were acquired without ECG-synchronization
and reconstructed using sharp and soft kernels. Coronary calcifications were annotated
employing the clinically used intensity value thresholding (130 HU). Thereafter, a threshold
separating each calcification from its background was determined using an ExpectationMaximization algorithm. Finally, for each lesion the partial content of calcification in each
voxel was determined depending on its intensity and the determined threshold.
Date made available10-Dec-2018
PublisherUtrecht University
Geographical coverageThe Netherlands
Access to the dataset Open
Contact researchdata@rug.nl

    Keywords on Datasets

  • Health, Radiology and Organ Imaging, calcium volume score, chest CT, NLST, Coronary artery calcium score, Phantom imaging, chest CT study, CEORA phantom, SATI phantom
Related Publications
  1. Coronary calcium scoring with partial volume correction in anthropomorphic thorax phantom and screening chest CT images

    Sprem, J., de Vos, B. D., Lessmann, N., van Hamersvelt, R. W., Greuter, M. J. W., de Jong, P. A., Leiner, T., Viergever, M. A. & Isgum, I., 20-Dec-2018, In : PLoS ONE. 13, 12, 20 p., 0209318.

    Research output: Contribution to journalArticleAcademicpeer-review

View all (1) »

View graph of relations